TECHNICAL SPECIFICATIONS
The CurrentX Series includes 4, 8, 12 and 16-channel low-level DC current data loggers.
Key Features:
- Available in 3 Ranges
- Memory Capacity of 4,000,000+ Readings
- Accepts Signals from Common Voltage Sources
General
| Memory | 4-channel: 1,048,064 readings per channel 8-channel: 524,032 readings per channel 12-channel: 349,354 readings per channel 16-channel: 262,016 readings per channel (all channels enabled) |
| Reading Rate | 4 Hz to 1 reading every 24 hours |
| Channels | 4, 8, 12, 16 |
| LED Indicators | 1 per channel and 2 status LEDs |
| Battery Life | 18 months |
| Material | Black anodized aluminum |
| Dimensions | 4-channel: 2.70 in x 7.25 in x 1.22 in (65.6 mm x 184.2 mm x 31.0 mm) 8-channel: 2.70 in x 7.25 in x 1.22 in (65.6 mm x 184.2 mm x 31.0 mm) 12-channel: 2.70 in x 7.25 in x 1.68 in (65.6 mm x 184.2 mm x 42.7 mm) 16-channel: 2.70 in x 7.25 in x 2.14 in (65.6 mm x 184.2 mm x 54.4 mm) |
| Operating Environment | -20 °C to +60 °C (-4 °F to +140 °F), 0 %RH to 95 %RH non-condensing |
Current
| Current Range | -2 mA to +30 mA, ±160 mA, ±3 A |
| Max Voltage: Inputs & Ground | 3 V (Common mode voltage must be less than 3 volts. All inputs must be within 3 volts of all other inputs.) |
| Current Resolution | 30mA: 0.0005 mA 160mA: 0.005 mA 3A: 0.001 A |
| Current Calibrate Accuracy | 30mA: ±0.016 mA 160mA: ±0.16 mA 3A: ±0.009 A |
| Current Input Impedance | 30mA: 10 Ω 160mA: 1 Ω 3A: 0.1 Ω |