Manufacturer : JP SELECTA

DETERMINATION OF ORGANIC NITROGEN (KJELDAHL METHOD) 
AUTOMATIC NaOH DOSAGE AND TEMPORIZE STOP


FEATURES 

  • Steam distillation system
  • Compact steam generator with safety over temperature thermostat and over pressure device
  • Safety door, the system will not operate if the door is open
  • “Tube in place” sensor: if the tube is not located, the dosing process of NaOH will not take place
  • Universal adapter for digestion/distillation tubes MACRO (Ø 42 mm) and MICRO (Ø 26mm) 
  • Small footprint, saves bench top space: The H2O and NaOH reservoirs are placed within the unit. Stainless steel case with reinforced ABS plastic front. Automatic distillate titration kit. (See accessories)

 

 

SPECIFICATIONS 

 

Measuring range: from 0.2 to 200 mg of Kjeldahl Nitrogen

Programmable distillation time

Nitrogen recovery >99.5% Distillation speed: from 35-40ml/minute 

Typical distillation time: from 7-10 minutes

Water consumption rate: from 80-100 litres/Hr

Steam generator water consumption: 2,5 Litres/ Hr

Water reservoir for steam generator: 6 litres 

NaOH reservoir: 2 Litres

 

 

ALARMS 

 

Low water level for the steam generator

Safety door open or no distillation/digestion tube in place

Steam generator over temperature

 

 

AUTOMATED SEQUENCES 

 

Open and closure of cooling water to the cooling coil. 

Automatic load of NaOH once the distillation has started. 

Select NaOH volume. 

Stop at the end of the pre-set programmed time. 

 

 

ADDITIONAL REQUIREMENTS 

 

To complete Kjeldahl Nitrogen analysis a digestion block is also required. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 