Laboratory Equipment :: Nutritional & water analysis :: Organic Nitrogen Determination (Κjedahl) :: Steam distillation unit KJELDAHL PRO-NITRO-S :: Main Solutions 
Mainsolutions.eu - Instruments Services
Mainsolutions.eu - Instruments Services Mainsolutions.eu - Instruments Services Mainsolutions.eu - Instruments Services
Mainsolutions.eu - Instruments Services Mainsolutions.eu - Instruments Services Mainsolutions.eu - Instruments Services

Products

Search

Manufacturers

Services

Calibrations (Accredited laboratory) Maintenance - Repairs Department of Cleanroom Validation (Lloyd's Register Certified)) IQ/OQ/PQ Temperature/ Humidity Mapping Occupational Health & Safety Measurements Validation Studies Vibration and Noise studies Laboratory Organization

Steam distillation unit KJELDAHL PRO-NITRO-S

Click on image to zoom

Steam distillation unit KJELDAHL PRO-NITRO-S

(Semi-automatic)

Manufacturer : JP SELECTA

DETERMINATION OF ORGANIC NITROGEN (KJELDAHL METHOD)

AUTOMATIC BORACIC AND NaOH DOSAGE, SAMPLE DRAINAGE AND TEMPORIZED STOP

Semi-automatic steam distillation Kjeldahl unit. Simple secure systematic analysis suitable for medium to large throughput of samples. 

 

 

FEATURES 

 

  • Steam distillation system. 
  • Compact steam generator with safety over temperature thermostat and over pressure device. 
  • Safety door, the system will not operate if the door is open. 
  • “Tube in place” sensor: if the tube is not located, the dosing process of NaOH will not take place. 
  • Universal adapter for digestion/distillation tubes MACRO (Ø 42mm) and MICRO (Ø 26 mm). 
  • Small footprint, saves bench top space: The H2O, NaOH and H3BO3 reservoirs are placed within the unit. 
  • Empty Digestion/Distillation tube system. Stainless steel case with reinforced ABS plastic front. 
  • Green LED 2 digit display. 
  • Distillation program: (Add NaOH, Add Boric Acid, Distillation time, Empty tube.) 
  • Automatic distillate titration kit. (See accessories). 

 

 

SPECIFICATIONS 

 

Measuring range: from 0.2 to 200 mg Nitrogen. 

Programmable distillation time. 

Nitrogen recovery >99.5% 

Distillation speed : from 35-40ml/minute 

Typical distillation time: from 7-10 minutes. 

Water consumption rate: from 80-100 litres/Hr. 

Steam generator water consumption: 2.5 Litres/ Hr. 

Water reservoir for steam generator: 6 litres 

NaOH reservoir: 2 Litres. Boric Acid reservoir: 2 Litres 

 

 

ALARMS 

 

Low water level for the steam generator. 

Safety door open or no distillation/digestion tube in place. 

Steam generator over temperature. 

 

AUTOMATIC

 

Single push button to start the distillation cycle: 

- Boric acid dosing 

- Start distillation. 

- NaOH dosing 

- Stop Distillation (Programmed time transpired.)

- Acoustic indicator at the end of the cycle. 

 

 

 

ADDITIONAL REQUIREMENTS 

 

To complete Kjeldahl Nitrogen analysis a digestion block is also required. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

We use cookies to give you the best experience on our site. If you continue to use the webpage, we will assume you are happy with it.
OK MORE