The simpler the design, the safer the lock! The lock can be opened and closed with one finger. Radially locking bolts are moved without applying any force.The passive chamber seal operates with virtually no wear.
Four Sizes
|
HV 25 |
Chamber volume of 28 L |
|
HV 50 |
Chamber volume of 54.2 L |
|
HV 85 |
Chamber volume of 98.8 L |
|
HV 110 |
Chamber volume of 123.7 L |
The lid gasket is not subjected to any mechanical friction and can easily be replaced if required. The weight of the lid is completely balanced by a torsion spring. Effortless opening and closing. Any condensate which drips off the lid is collected and fed into the spent-steam condenser. The device and floor are kept dry.
Programs at the push of a button
The most important programs are pre-installed and can be opened at the push of a button:
- Sterilization of solids: With fast release of steam
- Sterilization of liquids: With variable natural cooling
- Sterilization of liquids: With rapid cooling for thermolabile materials
- Sterilization of liquids: With subsequent reheat cycle
- AGAR program: Prepares AGAR and keeps it ready for processing (thermostatic heating)
- Night program: Timer-controlled, load in the evening - sterile and ready for removal in the morning down to the minute, even over the weekend!
- Waste sterilization: Mixed load with a low liquid content
- Automatic standby operation to save energy
Dual sensor system
Precise temperature control with additional pressure monitoring. This allows for controlled excess pressure during the heating phase, which reduces the batch time Bright display with program and progress indicators.
Thermolock with sterilization time control
The German ordinance on pressure vessels TRB 402 and DIN EN 61010-2 prescribe a thermolock for the sterilization of liquids. This thermolock prevents injuries do the operating personnel due to boiling delay. This hazard should be controlled directly in the substance at risk for boiling delay. The lid can only be opened once the media temperature has also dropped below the reference value after pressure equalization. All parameters can be set individually before starting the program, and cannot be modified after program start for safety reasons. Reliable sterilization is ensured in this manner.
Heating
- Electrical, with maximum efficiency, directly in the feed water
- 3-level protection against overheating
Exhaust air filter
Safety for individuals and the environment. Option for safe, emission-free sterilization of highly infectious germs and genetically modified materials. During the venting phase, the steam displaces unsterilized residual air from the chamber and passes it through a filter system. The surrounding air is protected against contamination as the cycle is running. Naturally, in-line sterilization of the exhaust air filter is performed. Due to the design, condensate sterilization is a matter of course. Any condensate which precipitates flows back into the chamber and gets sterilized. Discharge can be done safely.
| HV Technical Data |
|
HV 25 |
HV 50 |
HV 85 |
HV 110 |
| Chamber volume | Litres | 28 | 54,2 | 98,8 | 123,7 |
| Useful volume | Litres | 25 | 50 | 85 | 110 |
| Chamber dimensions Ø x H | mm | 240 x 550 | 300 x 710 | 420 x 615 | 420 x 795 |
| Exterior dimensions W x D x H | mm | 480 x 460 x 950 | 540 x 530 x 1040 | 660 x 650 x 1000 | 660 x 650 x 1180 |
| Required space W x D x H | mm | 495 x 750 x 1250 | 560 x 810 x 1400 | 680 x 930 x 1450 | 680 x 930 x 1650 |
| Selectable operating temperature | °C | 105° - 126° | 105° - 135° | 105° - 128° | 105° - 123° |
| Allowable operating temperature | 130° | 139° | 133° | 127° | |
| Maximum operating pressure | bar | 1,4 | 2,2 | 1,6 | 1,2 |
| Electrical power | kW | 1,5 | 2,0 | 3,0 | 4.0* |
| Weight | kg | 41 | 57 | 71 | 81 |
| Warming temperature | °C | 45° - 60° | |||
| Special cycle | °C | 60 - 100 °C for preparing culture media | |||
| Automatic start | 1 minute to 7 days | ||||
| Sterilization time | t | 1 to 250 minutes | |||
| Lock | Quick lock with one-lever operation | ||||
| Power supply | V | AC 220 V/240 V | |||
| Safety systems | Electro-mechanical safety lock, safety valve, low-water interrupt, overpressure protection switch, overheating protection switch, circuit breaker, fault indicator (visual and audible) |
||||
| Vessel material | SUS304 (high-grade stainless steel) | ||||
| Documentation | Integrated printer/USB (optional) | ||||
| Item Number | 20000 | 20001 | 20002 | 20003 | |