Étalonnages (Laboratoire accrédité) Maintenance - Réparations IQ/OQ/PQ Validation/ Cartographie de la température et de l\'humidité Contrôles Santé et Sécurité Études de validation Études de Vibration et de Bruit Organisation de Laboratoire

MA Series

Click on image to zoom

MA Series

Jauges de pression absolue

SPECIFICATIONS TECHNIQUES

 

• Nominal sizes
- 100 and 150.

 

• Models
- MA 325: ranges included between 0,6 and 2,5 bar absolute;
- MA 425: ranges included between 25 and 400 mbar absolute;

 

• Casing
- case and ring in AISI 304 stainless steel (AISI 316 on request - option V61) with bayonet bezel.

 

• Protection degree (according to EN 60529)
- IP 55 standard - dry execution;
- IP 65 not fillable (option V72).

 

• Window
- glass;
- laminated safety glass (on request - option V17).

 

• Blow out device
- blow out plug.

 

• Pressure connection (according to EN 837)
AISI 316L stainless steel threaded G 1/2 B (1/2 Gas or BSP) or 1/2-14 NPT EXT (1/2 NPT).

 

• Pressure element
- AISI 316Ti stainless steel diaphragm.

 

• Movement
- stainless steel.

 

• Ranges (according to EN 837)
o Scale ranges 
for pressure values between 25 mbar and 2,5 bar abs:
- see table B1 at page P06; (divisions as per table C1 at page P08);
- other graduations not normalized for single or double range (on request).


o Unit of pressure:
- mbar, bar, kPa, kg/cm2 and psi for single or double range.
o Scale angle:
- 270 ° (180 ° for range 0÷25 mbar).

 

• Pointer
- aluminium with micrometer adjustment.

 

• Dial
- white aluminium with black figures (for dial modifications see available options).

 

• Accuracy (according to EN 837)
- class 1,6 (± 1,6% of full scale deflection).

 

note 1: accuracy class is not affected by atmospheric pressure changes.
note 2: accuracy indicated on the pressure gauge does not consider the interference of on eventually applied electric contact.

 

• Ambient temperature
- -20÷+60°C.

 

• Operating temperature
- max 120°C.

 

• Thermal drift
- out of the optimum ambient temperature values included within +15 ÷ +25°C, the thermal drift affects the instruments accuracy as follows:
- 0,3% every 10°C for model MA 325;
- 0,5% every 10°C for model MA 425.

 

 