Condensation Fog Generator

Κατασκευαστής :

CFG 291 FOG GENERATOR


Condensation Fog Generator CFG 291 for fog generation to visualise air flows according to ISO 14644-3

The mobile fog generator CFG 291 is used to generate a highly visible, stationary fog for visualising air flows. It combines the handy design of the previous model CFG 290 with optimised fluid guidance and a specially developed evaporator.


The fog generator is primarily used for the initial acceptance and routine inspections of cleanroom systems in accordance with the standard series ISO 14644 or guideline VDI 2083-3 in order to detect leaks in the transition areas of cleanroom elements, to prove the presence of laminar displacement flow or to visualise the overpressure level of cleanrooms.

 

Benefits

  • operation in different orientations possible (hermetically sealed fluid tank)
  • nearly continuous operation (use of replaceable batteries)
  • easy on-site replacement of the evaporator cartridge by the customer
  • low-impulse fog input into ambient air stream (special discharge probe)

 

Applications

  • visualisation of air flows in rooms
  • standard-compliant acceptance and routine testing of cleanroom systems
  • visual leak testing of rooms or enclosed areas
  • function testing of various sensors (smoke detectors, PM sensors)

 

Technical data
Parameter title Unit Value
purpose of use - visualisation of gas flows
sample condition, outlet - highly visible, stationary fog
operating medium, liquid - fog fluid (TopFog Regular, TopFog Light)
operating medium, liquid - composition - main components triethylene glycol, glycerine and ultrapure water
operating medium, liquid - filling volume mL max. 60
operating medium, Flüssigkeit - consumption ml/min 1,70
power supply - lithium-ion accumulator; 3 cells (see product sheet)
dimensions (l × h × d) mm  
weight kg 1,2
operation time min 25

 

 

 

 

 

 

 