Διακριβώσεις (Διαπιστευμένο Εργαστήριο από το ΕΣΥΔ) Συντηρήσεις - Επισκευές Εργαστήριο Mέτρησης καθαρών χώρων (με Πιστοποίηση Lloyd's) Έλεγχοι Καταλληλότητας (IQ/OQ/PQ) Temperature/ Humidity Mapping Μετρήσεις υγείας & ασφάλειας Μελέτες επικύρωσης Μελέτες δόνησης & θορύβου Οργάνωση ΕργαστηρίουMagnus 22
ΤΕΧΝΙΚΑ ΧΑΡΑΚΤΗΡΙΣΤΙΚΑ
Max capacity 4 x 750 ml
Screen Type TFT
Max speed 21.948 xg / 14.300 RPM
Features
TFT color touch screen, visible from more than 3 m.: • Shows RPM and RCF, time, acceleration/deceleration values (PCBS) and unbalance location system (ULS). • Speed programming in 10 RPM/10 xg steps. • Real RCF values on screen based on accessories configuration. • Count up/down from “0” or at “set RPM/RCF” for reproducible tests. • Timer from 1 sec to 99 hours programmable in 1 sec. steps and hold position. • PCBS: Progressive controlled acceleration and braking system up to 175 selectable ramps that prevents sample homogenization after separation. • ULS: Unbalance location system indicating on the screen the number of the bucket which produces the unbalance switch off. • Start delay: To program the time at which the cycle is to begin. • Linked program: Permits the linking of up to 8 consecutive programmes without the need of user intervention. • 100 programmable memories, with protection under password. • Several acoustic and visual messages showing the situation of the device to the user.
Easy to use
• Microprocessor controlled. Connectivity. • Induction motor maintenance free (brushless). • Rotors and adapters list in memory. • Noise level: below 60 dB. • Start, stop, open lid and short spin with adjustable speed buttons. • Possibility to block or modify the speed during the cycle. • Automatic lid opening, programmable. • Last values remain in memory • Automatic rotor recognition. Over-speed protection.
Safety
• Lid provided with security systems: - Automatic lid lock system, motorized with double lock. - Emergency lid-lock release. - Locking and protection against opening along the run. - Lid dropping protection. - Port in the lid for calibration and operation checking. • Unbalance detection and switch off. • Protection safety ring between the centrifugation chamber and the housing. • Chamber of centrifugation in stainless steel (easy cleaning). • Rotors can be removed with the lid closed. Hermetic lids. • Rotors and adapters autoclavable, easy to install by the user. • Forced ventilation to reduce temperature increasing. • Automatic disconnection for energy saving up to 8 h., with deactivation option.
EU Directives: 2011/65/EU, 2012/19/EU, 2014/30/EU, 2014/35/EU, 2017/746/EU. Standards: EN 61010-1, EN 61010-2-101, EN 61010-2-020, EN 61326-2-6, EN 61326-1.